GearUP AVP-63 Automatic Voltage Protector-220V
Key FunctionsProtection Features  Over-voltage Protection: Cuts off power if voltage exceeds the set threshold (P-3).  Under-voltage Protection: Disconnects load if voltage drops below the set limit (P-5).  Over-current Protection: Trips when current surpasses the configured max (P-9) after a delay (P-10).  Automatic Recovery: Restores power after fault conditions (adjustable via P-15).  Fast Power-Down: Emergency cutoff (enabled via P-14).Monitoring & Display  Real-time voltage display (AC/DC).  Real-time current display (AC only; DC mode shows voltage only).  Indicators for faults (>V, A) and normal operation (POWER).Programmable Settings  Adjustable thresholds for voltage/current, recovery times, and calibration (P-1 to P-17).  Password protection (P-17) to prevent unauthorized changes.2. Technical Specifications3. Setup & Operation GuideA. Initial ConfigurationPower Connection:  Wire terminals (N-L) to AC/DC source within rated limits.Menu Navigation:  Use front-panel buttons to adjust parameters (P-1 to P-17).B. Critical SettingsC. CalibrationVoltage: Adjust via P-8 (±10%).Current: Calibrate with P-12 (±10%).Frequency (AC only): Fine-tune with P-13 (±2.5%).D. Safety & RecoveryManual Reset: Required if auto-recovery (P-15) is disabled.Event Logging: Overcurrent counts (P-11) track fault history.4. Usage NotesDC Mode: Current display disabled; only voltage monitored.Energy Saving: Enable P-16 to reduce idle power consumption.Altitude Warning: Performance may degrade above 2000m.Note: Refer to the device’s manual for detailed wiring diagrams and safety compliance.
Saqlain e Store
Category List
All products

Details:
- Warrantyyear (Burn and physical damage not applicable)
Key Functions
Protection Features
- Monitoring & Display
- Programmable Settings
2. Technical Specifications
3. Setup & Operation Guide
A. Initial Configuration
Power Connection:
- Menu Navigation:
B. Critical Settings
C. Calibration
Voltage: Adjust via P-8 (±10%).
- Current: Calibrate with P-12 (±10%).
- Frequency (AC only): Fine-tune with P-13 (±2.5%).
D. Safety & Recovery
Manual Reset: Required if auto-recovery (P-15) is disabled.
- Event Logging: Overcurrent counts (P-11) track fault history.
4. Usage Notes
DC Mode: Current display disabled; only voltage monitored.
- Energy Saving: Enable P-16 to reduce idle power consumption.
- Altitude Warning: Performance may degrade above 2000m.
Note: Refer to the device’s manual for detailed wiring diagrams and safety compliance.
GearUP AVP-63 Automatic Voltage Protector-220V
950 BDT1,050 BDTSave 100 BDT
1
Details:
- Warrantyyear (Burn and physical damage not applicable)
Key Functions
Protection Features
- Monitoring & Display
- Programmable Settings
2. Technical Specifications
3. Setup & Operation Guide
A. Initial Configuration
Power Connection:
- Menu Navigation:
B. Critical Settings
C. Calibration
Voltage: Adjust via P-8 (±10%).
- Current: Calibrate with P-12 (±10%).
- Frequency (AC only): Fine-tune with P-13 (±2.5%).
D. Safety & Recovery
Manual Reset: Required if auto-recovery (P-15) is disabled.
- Event Logging: Overcurrent counts (P-11) track fault history.
4. Usage Notes
DC Mode: Current display disabled; only voltage monitored.
- Energy Saving: Enable P-16 to reduce idle power consumption.
- Altitude Warning: Performance may degrade above 2000m.
Note: Refer to the device’s manual for detailed wiring diagrams and safety compliance.